Battery performance
|
Industry standard requirements
|
Product actually reached level
|
10 hours rate capacity
|
95% for the third time
|
95% for the first time
|
3 hours rate capacity
|
Fourth reaches capacity
|
One is in excess of the prescribed capacity by 10%
|
1 hour rate capacity
|
95% for the fifth time
|
One is in excess of the prescribed capacity by 10%
|
Large current discharge
|
3 minutes to 30 i10a discharge not fuse
|
Conform
|
Charged retention (self-discharge)
|
28 days of no less than 96% (less than 4%)
|
Conform (less than 2%)
|
Sealed reaction efficiency
|
No less than 95%
|
> 98% (H, O2 inner loop reaction into water, can reach more than 99%)
|
Charging life
|
2 v240 days, 6 v above 180 days
|
570 days
|
Battery connection bar pressure drop
|
≤10mv
|
6mv
|
The relief valve required
|
Closed 1-15 Kpa pressure valve 10 ~ 35 Kpa pressure
|
Closed pressure < 15 kpa, open the valve pressure, 15 to 25 kpa
|
Explosion-proof performance
|
Don’t burst
|
Conform
|
The sealing performance
|
- 30 ℃ is not crack, 65 ℃ is not crack, not flow
|
Conform
|
The acid mist performance
|
Acid mist fold the < 0.025 mg/AH, or PH is neutral
|
0.008 mg/AH, PH is neutral
|
Open circuit voltage difference
|
2V 0.03V、6V0.04V、12V 0.06V
|
2V 0.02V 12V 0.05V (a group of battery voltage difference)
|
Air tightness
|
50KPAPositive and negative pressure does not crack, not open, deformation
|
60 kpa positive and negative pressure, no crack, deformation and would not open
|